  • What is the requirement of storing sterile?

    First, the environmental requirements
    1, the sterilized items should be stored in sterile storage room or storage cabinet storage racks, storage racks or lockers should be easy to clean, rust; preservation of the environment should be clean, bright, airy or air purification devices, illuminating light adequate; the temperature is below 24 ℃, humidity below 70%.
    2, sterilized items should be classified storage, disposable sterile items should be removed from the outer Bulk storage, storage location is relatively fixed, clear identification; items should be stored away from the ground 20 ~ 25cm, from wall 5 ~ 10cm, from the ceiling 50cm.
    3, the operating room, treatment room, dressing room with natural ventilation, poor ventilation can be used when the exhaust fan forced ventilation; sterile items should be cleaned daily to preserve the environment, surface and ground wet wipe, to avoid dust .
    4, to establish a working record.
    Second, the personnel requirements
    1, sterile storage areas should be someone responsible for the management; wash your hands before touching sterile items.
    2, when the inventory items to visual-based, reducing touch.
    3, placing sterile items should be placed in order according to the expiration date, valid flag prominently near expired items on access to convenient location; disposable sterile supplies should be placed in a batch and then run out the next batch or the remaining batches of a small amount of unused items on top.
    Third, sterile validity
    1, sterile no seasonal restrictions preserve validity, save different expiration date on the basis of different packaging materials should be used carefully review the validity flag.
    2, sterilized items should be clean and easy to loose packing, sealing, no holes, sterilization and expiration date clearly marked, according to the validity of the order code on the store shelf or storage cabinet, valid flag should express, easy visual inventory.
    3. Save the validity sterile
    (1) using sterile cotton packing material: preservation of the environment can be extended to meet the requirements of the valid 14 days; preservation of the environment can not meet the requirements of various clinical, medical departments, valid for seven days storage of sterile items. In case of rainy weather or dusty weather continued retention period should be reduced.
    (2) the use of disposable packaging materials packaging sterilization, sterile items, save the environment clean, relatively stable temperature and humidity conditions:
    ① medical disposable paper bags will be valid for one month.
    ② disposable medical crepe paper, disposable paper and plastic bags, medical non-woven packaging is valid for six months.
    ③ sealed rigid container package is valid for six months.
    (3) preservation of the environment sterile suspected contamination, moisture or when the quality of the sterilization packaging bag doubt, you should stop using and re-package goods cleaning, packaging and sterilization.
    4, open tank, equipment boxes and other packaging materials can not be used for sterilization.
    5, sterilizer manufacturers guidance is inconsistent with national norms, follow strict principles.
    Fourth, the use of sterile goods inventory
    1, before inventory or access to sterile wear hats, masks, hand washing hygiene.
    2, should be used when the inventory of non-sterile hand-touch approach to visual-based, must hand touch when inventory should be gently, focus your items to preserve the environment is clean, articles validity sterilization process indicator color, sterilization package appearance quality.
    3, should be used carefully view sterile packaging quality, validity and package goods quality.
    4, according to the order in order to open the sterile package, prohibit the use of the following circumstances:
    (1) sterilization items exceeding the prescribed period of validity;
    (2) sterile goods packaging loose or have holes in the cloth bag;
    (3) cloth wet with stains, watermarks or water damage;
    (4) the sterilization process indicator tape did not change color or uneven color;
    (5) chemical sterilization indicator card package does not change color or uneven color;
    (6) sterilizing instruments stains, rust stains;
    (7) on the quality of the sterilization process and expressed suspicion.
    5, sterile items should be cleaned after use, equipment and packaging classification is placed in the specified location; clean up the goods delivered or when the weapon accidentally stabbed himself or those around the weapon promptly after use into the tool box.
    6. Wash your hands after the end of any clinic operations, but also to take off the gloves and wash hands after.